Model 6280
6270 with Sipper
Set-Up Screen
Measurement Screen

Click here to Buy Now

62 Series Fluorimeters

• High quality optics: pulsed xenon lamp and Total Energy Transfer (TET)
• Intelligent Filter Modules ensure correct filters are fitted for selected method
• Intuitive programming allows fast program creation
• Raw fluorescence or concentration values options
• Standard curve and kinetic functions
• Heated sample holder and sipper pump accessories
• Compatible with DataWay PC software
• 3 year warranty

Jenway offers three fluorimeter models to cover a wide range of applications and fluorscence measurements. The 6280 fluorimeter model is ideal for the most sensitive determinations with emission wavelengths up to 650nm. When higher emission wavelengths are required the 6285 fluorimeter with its red-enhanced detector is the unit of choice. For less sensitive applications and a broader wavelength range up to 1100nm the low cost 6270 fluorimeter unit is more
suitable.

With press-to-read operation and Total Energy Transfer (TET) technology the output of the high-energy xenon lamp is maximised and its expected life extended so that it should never need replacing within the normal lifetime of the unit. The high quality optics are complemented by the Intelligent Filter Modules (IFM) that are identified by the unit, generating error messages should the wrong filters be fitted or their positions be incorrect.

Each fluorimeter model offers intuitive operation with a user interface based on logical menus that can be navigated from the simple keypad. Up to 20 methods can be created without restriction and saved for future use. They can also be locked against accidental change by password entry. The permanent time and date tag on every stored reading supports Good Laboratory Practice, while calibration reminders and operator identity can also be entered to support conformance and traceability of results.

All fluorimeter models are powered from an external, universal mains adapter suitable for use from 90V to 230V.

Features

Feature 62 Series Fluorimeter
Wavelength selec tion Intelligent Filter Modules (IFM)
Light source Pulsed Xenon lamp with press-to-read operation
Expected life of lamp No replacement required in normal operation
Raw fluorescence readings Yes
Concentration standard curve Blank + up to 6 standards
Kinetics, timed option In both raw fluorescence and concentration modes
Kinetics options 1 reading every 3 to 999 seconds
No. methods stored 20
No. results stored 100 per method
GLP Method lock with password access. Time and date stamped results. Last calibration date and time stored. Calibration interval set. Calibration due reminder. User ID
Outputs RS232
PC software Compatible with DataWay (option)
Sample handling 10mm square cuvette holder (standard). Heated sample holder (option). Sipper pump (option)
Power supply 90 to 230V universal mains adapter 12V DC input
Size (w x d x h) 365 x 272 x 160mm
Weight 6kg


Technical Specification

Parameter 6270 6280 6285
Wavelength range 190 to 1100nm 190 to 650nm 190 to 850nm
Sensitivity1 1µg/ml <1ng/ml <1ng/ml
Dynamic range1 5.2x104 5.2x106 5.2x106
Detector Photodiode PMT2 PMT2

1 Using quinine sulphate
2 Photomultiplier tube

Ordering Information

Part Code Description
627 001 6270 fluorimeter supplied with 100 disposable cuvettes and mains adapter for use on 90 to 230V supply with UK, Euro and US mains leads
628 001 6280 fluorimeter supplied with 100 disposable cuvettes and mains adapter for use on 90 to 230V supply with UK, Euro and US mains leads
628 501 6285 fluorimeter supplied with 100 disposable cuvettes and mains adapter for use on 90 to 230V supply with UK, Euro and US mains leads


Note: Excitation and emission filters are not included and should be purchased as separate items. Please refer to the filter section.


Return to Category